Technicial Specifications
Standby Rating | 2250 ekW 2250 ekW |
Prime Power Rating | 1825 ekW 1825 ekW |
Emissions/Fuel Strategy | Low Fuel, Low Emissions Low Fuel, Low Emissions |
Voltage | 380 to 13800 Volts 380 to 13800 Volts |
Frequency | 60 Hz 60 Hz |
Speed | 1800 rpm 1800 rpm |
Duty Cycle | Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous |
Maximum Rating | 2250 ekW 2250 ekW |
Minimum Rating | 1640 ekW 1640 ekW |
Engine Model | 3516B TA, V-16, 4-Stroke Water-Cooled Diesel 3516B TA, V-16, 4-Stroke Water-Cooled Diesel |
Bore | 6.69 in 170 mm |
Stroke | 7.48 in 190 mm |
Displacement | 4210.64 in 69 l |
Compression Ratio | 14.0:1 Std 15.5:1 HD 14.0:1 Std 15.5:1 HD |
Aspiration | TA TA |
Fuel System | Electronic unit injection Electronic unit injection |
Governor Type | Adem™3 Adem™3 |
Length - Maximum | 251.4 in 6385 mm |
Width - Maximum | 90 in 2286 mm |
Height - Maximum | 98.2 in 2494 mm |
Dry Weight - Genset (maximum) | 31270 lb 14180 kg |
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
Cat ECS Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50�C (122�F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- UL 2200 Listed
- CSA
- IBC seismic certification
- OSHPD pre-approval
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment
-
Air Inlet System
- Air cleaner; single element canister type
-
Cooling
- Package mounted radiator
-
Exhaust
- Exhaust flange outlet
-
Fuel
- Primary fuel filter with integral water separator
- Secondary fuel filters
- Fuel priming pump
-
Generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
-
Power Termination
- Busbar
-
Control Panel
- Cat ECS Genset controller
-
General
- Paint - Caterpillar yellow except rails and radiators gloss black
-
Control Panels
- Speed adjust
- Text alarm/event descriptions
- Generator set packages include Caterpillar's voltage regulator
- Auto/start/stop control
- 24 Volt DC operation
- Cat ECS 100
- Generator mounted - Rear facing
- Controls:
- Environmental sealed front face
- Engine cool-down timer
- Emergency stop pushbutton
- Limiter and exciter diode monitor
- Engine cycle crank
- Lamp test
- Alarm acknowledge
- Customizable screens
- PLC functionality
- Load histogram feature
- 0 True RMS AC metering, 3-phase, +/-2% accuracy
- Operating hours
- Digital indication for:
- DC volts
- RPM
- Coolant temperature
- Amps (per phase & average)
- Oil pressure (psi, kPa or bar)
- Volts (L-L & L-N)
- Frequency (Hz)
- Power factor (per phase & average)
- kW (per phase, average & percent)
- High coolant temperature
- Low oil pressure
- Warning/shutdown with common LED indication of shutdowns for01/10/2018:
- kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- kVAr (per phase, average & percent)
- Emergency stop
- Overspeed
- Failure to start (overcrank)
- Programmable protective relaying functions:
- Low coolant temperature
- Generator phase sequence
- Low coolant level
- 1 Programmable digital outputs
- Gear type lube oil pump
- Battery disconnect switch
- Caterpillar yellow with high gloss black rails and radiator
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Medium voltage: Form wound - Permanent magnet excitation (PMG) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - Busbar connections, right side extension box, bottom cable entry - NEMA standard hole pattern
- Fumes disposal
- Permanent magnet excitation (PMG)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Permanent magnet excitation (PMG)
- NEMA standard hole pattern
- Reverse reactive power (kVAr) (32RV)
- Over/under voltage (27/59)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Permanent magnet excitation (PMG)
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- Permanent magnet excitation (PMG)
- SAE standard rotation
- Internal excitation (IE)
- Flexible fuel lines - shipped loose
- IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min / max exciter
- Busbar connections, right side extension box, bottom cable entry
- Medium voltage:
- Communications:
- NEMA standard hole pattern
- Lubricating oil
- Oil drain lines and valve
- 3 Phase brushless, Salient pole
- 24 Volt electric starting motor
- 6 Customer programmable digital inputs
- Dry exhaust manifold
- Accessory module data link
- ADEM A3
- Form wound
- ATAAC - 3516E package radiators shipped installed
- Busbar connections, top center mounted, top cable entry
- High voltage:
- 4 Programmable relay outputs (Form A)
- Anti-condensation space heater
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
- NEMA standard hole pattern
- 45 Amp Charging alternator
- 3 Analog inputs
- Random wound
- Anti-vibration mounts (shipped loose)
- Cat connect
- Oil filter, filler and dipstick
- Rails - Engine/generator/radiator mounting
- Customer data link (Modbus RTU)
- Flywheel and flywheel housing - SAE No. 00
- English
- Busbar connections, right side extension box, bottom cable entry
- Serial annunciator module data link
- Integral lube oil cool
- Certified standard PGS provided
- Winding temperature detectors
- 1 Programmable relay outputs (Form C)
- Reverse power (kW) (32)
- Form wound - Permanent magnet excitation (PMG)
- Right hand servicing
- Overcurrent (50/51)
- 6 Lead
- Flanged faced outlet(s)
- Low voltage:
- Number of I/O varies on options selected
- Battery and battery rack w/cables
- Over/under frequency (81 o/u)
- Fuel cooler; not included with packages without radiator
- Busbar connections, right side extension box, bottom cable entry
- Rubber anti-vibration mounts - shipped loose
- NEMA standard hole pattern
Optional Equipment
-
Control System
- EMCP 4.4
-
Air Inlet System
- Single element filter
- Dual element air cleaner
-
Exhaust
- Exhaust mufflers
-
Generator
- Permanent magnet excitation (PMG)
- Internal excitation (IE)
- Anti-condensation heater
- Oversize and premium generators
-
Cooling System
- Water level switch gauges
- Standard ambient radiators
- Coolant
- Standard ambient ATAAC radiators
- Optional installed ATAAC radiators
- Air inlet protection including air shut off magnetic switch
- Optional installed radiator
-
Power Termination
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
-
Control Panels
- Generator temperature monitoring & protection
- Remote monitoring software
- Load share module
- Digital I/O module
-
Exhaust System
- Exhaust Offset
- Flanges
- Elbows
- Y Adapters
- Flange and exhaust expanders
- Clean emission parets
- Mufflers
- Flexible fittings
-
Fuel System
- Primary fuel filter
-
General
- Special paint
- US aid emblem
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EEC Declaration of Conformity
- Integral & sub-base fuel tanks
- Enclosures: Sound attenuated, weather protective
- Integral & sub-base UL listed dual wall fuel tanks
- EU Certificate of Conformance (CE)
- The following options are based on regional and product configuration:
- Automatic transfer switches (ATS)
- UL 2200 package
-
Mounting
- Rubber anti-vibration mounts
- Spring type vibration isolators
- IBC isolators
-
Generators and Attachments
- Generator conversions - IE and PM
- 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 Frame
- 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, IE, No. of leads: 6, Picth: 0.6667 - 1600 Frame
- 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 and 1800 Frames
- Alternator air cleaner
- Space heater
-
Intrumentation
- Pyrometer and thermocouples
-
Lube System
- Prelube pump groups
- Oil lever regulator
- Lube oil
-
Starting/Charging
- Battery chargers
- Air starting motor with control and silencer
- Heavy duty starting system
- Oversize batteries
- Charging alternator
-
Crankcase Systems
- Crankcase protection group: No explosion relief valves; Explosion relief valves
- Crankcase ventilation system
-
Mounting System
- Spring type vibration isolators
- IBC vibration isolators
- Puck style low efficiency isolators
-
Power Connections
- Neutral ground connections
- Center post busbarss
- Right, left side and rear power connections
- Grounding groups
-
Special Tests / Reports
- Standard engine test charge
- IBC Certification
- Special package tests: PGS Test report @ 1.0 and 0.8 power factors
- Generator set test report
- CSA Certification
- Torsional vibration analysis TVA report
- Fuel consumption test
-
Starting / Charging Sytem
- Jacket water heaters