Technicial Specifications
Maximum Rating | 450 kVA 450 kVA |
Minimum Rating | 350 kVA 350 kVA |
Emissions/Fuel Strategy | Low Fuel, R96/EUIIIa Low Fuel, R96/EUIIIa |
Voltage | 380 to 415 Volts 380 to 415 Volts |
Frequency | 50 Hz 50 Hz |
Speed | 1500 rpm 1500 rpm |
Duty Cycle | Standby, Prime Standby, Prime |
Engine Model | C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel |
Bore | 5.12 in 130 mm |
Stroke | 6.18 in 157 mm |
Displacement | 762.8 in³ 12.5 l |
Compression Ratio | 16.3:1 16.3:1 |
Aspiration | Air to Air Aftercooled Air to Air Aftercooled |
Fuel System | MEUI MEUI |
Governor Type | Adem™A4 Adem™A4 |
Length - Maximum | 186.7 in 4743 mm |
Width - Maximum | 79.3 in 2014 mm |
Height - Maximum | 84 in 2133 mm |
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.3 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment
-
Air Inlet System
- Turbocharger
- Aftercooler core
- Air cleaner; light duty with disposable paper filter
-
Control Panel
- GCCP 1.3
-
Cooling System
- Radiator and cooling fan with guard
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Coolant drain line with valve
-
Exhaust System
- Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
-
Fuel System
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
-
Generator and Attachments
- Power center, IP22
- Segregated low voltage (AC/DC) wiring panel
- Optional LC Frame generator - IP23 Protection
- Integrated voltage regulator (IVR)
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- A Frame generator - IP21 Protection
-
Packaged Generator Set
- Coolant drain line with valve
- Disposable air filter
- Coolant level sight gauge
- Low coolant level sensor
- Radiator package mounted
- Service indicator
-
Governing System
- Cat electronic governor (ADEM A4)
-
Lube System
- Oil drain valves
- Lubricating oil
- Oil cooler
-
Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
-
Starting / Charging System
- 24V battery with rack and cables
-
General
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
-
European Certificates
- Global Certification for CIS
- EU Certificate of Conformance (CE)
-
Air Inlet System
- Dual element air cleaner
- Single element air cleaner
-
Circuit breakers
- Power terminal strip
- 3 Pole (IEC-100% rated) Circuit breakers - Motorised
- Circuit breaker (IEC) Auxiliary contacts
- 4 Pole (IEC-100% rated) Circuit breaker - Motorised
- Padlockable circuit breaker device
- Shunt trip for IEC circuit breaker
- 3 Pole (IEC-100% rated) Circuit breaker
- 4 Pole (IEC-100% rated) Circuit breaker
-
Control Panels
- GCCP 1.4
- Volt free contacts
- Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
- Local alarm modules: Local annunciator
- Remote annunciator module
-
Cooling System
- Stone guards
- Radiator duct flange
- Low coolant temperature alarm
-
Enclosures
- High ambient sound attenuated enclosures
- Sound attenuated enclosures
-
Exhaust System
- 10, 25 and 35 dBA attenuation
- Mufflers - End in/end out
- 6 and 8 inch flange GP
- 6 and 8 inch elbow kit
- Flexible 8 inch exhaust fittings
-
Fuel System
- Manual fuel transfer pump
- Integral dual wall fuel tank base
- Fuel transfer system controls
-
Generator and Attachments
- A Frame oversize generator
- Permanent magnet excitation (PMG) generator
- Ingress protection
- A Frame CIP generator
- LC frame generator
- LC CIP generator
- Space heaters
-
Lube System
- Manual sump pump
-
Mounting System
- Narrow skid base
-
starting / Charging System
- Battery disconnect switch
- 5 Amp single Battery charger
- Jacket water heater