CHP1500

CHP1500

G3512H Combined Heat and Power (CHP) Solution Gas Generator

Continuous Rating 1490 ekW @ 1.0pf 1490 ekW @ 1.0pf
Fuel Type Natural Gas Natural Gas
Maximum Electrical Efficiency 42.50% 42.50%

Technicial Specifications

Generator Set Specifications
Continuous Rating 1490 ekW @ 1.0pf 1490 ekW @ 1.0pf
Fuel Type Natural Gas Natural Gas
Maximum Electrical Efficiency 42.50% 42.50%
Frequency 60 Hz 60 Hz
RPM 1500 rpm 1500 rpm
Frequency 60 Hz 60 Hz
Engine Specifications
Engine Model G3512H G3512H
Displacement 3574 in³ 59 l
Aspiration TA TA
Bore 6.7 in 170 mm
Stroke 8.5 in 215 mm
Fuel System Electronic Fuel Control Valve Electronic Fuel Control Valve
Governor Type ADEM™ A4 ADEM™ A4
Compression Ratio 11.1 11.1
Generator Set Dimensions
Length 716 in 18200 mm
Width 155 in 3940 mm
Height 467 in 11850 mm
Dry Weight - Genset 34700 lb 15740 kg
Weight 161600 lb 73500 kg

Advantages and Features

Cat® G3516H Humidity Fuel Tolerant Gas Engine

  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection

CHP Ready

Extensive range of rental ready features to meet job requirements and applications.

Single-Source Supplier

Generator set manufactured in ISO 9001:2000 compliant facility.Package factory designed and production tested.

EMCP 4.3 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cat Generator

Cat SR5 generator designed to match the performance and output characteristics of the Cat Gas engine.Class H insulation operating at Class F temperature rise for extended life.System 4 insulation protection and anti-condensation space heaters.Integrated Automatic Voltage Regulation (Cat IVR) provides enhanced system monitoring.

Fuel/Emissions Strategy

Meets most worldwide emissions requirements down to 500 mg/Nm3 NOx level without after treatment.Optional: Oxidation catalyst available

Sound Attenuated Container

Meets 75 dB(A) at 7 meters. Weather Proof enclosure, NSPS factory compliant, UL2200 compliant, and CSA/TSSA. Service and Personnel doors. Separate electrical control room. Internal and External emergency stop buttons at convenient locations.

Proven System

  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available

Reduced Environmental Impact

110% spill containment of onboard engine fluids.Positive crankcase fumes ventilation.

Full Range of Attachments

  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation

Worldwide Product Support

Cat® dealers provide extensive post sale support including maintenance and repair agreements. Supported 100% by the Cat dealer with warranty on parts and labor.

Cooling System

Provides 40⁰C (104⁰F) ambient capability with 500 mg/Nm3 NOx (1g/hp-hr) at 100% continuous rating before derate @ 500m. Variable frequency drive fan controls improve partial load fuel consumption. Energy efficient electric drive fan.

Standard Equipment

  • Engine
    • G3512H, V12, 4-stroke-cycle, gas engine. Operates on 31.5 to 47.2 MJ/NM3 dry pipeline natural gas. Turbocharged Separate Circuit Aftercooled.
  • Air Inlet
    • Package Mounted Air Cleaner with service indicator
  • Control Panel
    • On Package EMCP 4.3 Control Panel System Offers engine and generator monitoringand protection, voltage regulation with Cat IVRimproves transient response performance. Controls provide auto paralleling AGC-4 controller, load sharing, VFDcontrol, and primary generator protection for greaterversatility, package utilization and monitoring.
  • Cooling
    • ANSI/DN customer flange connections for JW inlet and outlet
    • Engine driven water pumps for jacket water and aftercooler
    • Jacket water and SCAC thermostats
    • Standard cooling provides 40⁰C (104⁰F) ambient capability with 500mg/Nm3 NOx at 100% Continuous rating before derate, @ 500m
  • Containerized Module
    • NSPS Factory Compilant, UL2200 Compilant and CSA / TSSA Sound attenuated 75 dB(A) @ 7 m (23 ft) Sound attenuated air intake louvers and lockable personnel doors with panic release LH and RH engine service doors integrated intocontainer side walls 3” ANSI flange customer fuel connection
  • Generator Controls And Protection
    • Integrated crankcase ventilation system (CCV)and gas fuel train NFPA37 & CSAB149.3 with external fuel connections package utilization and monitoring.
  • Modes of Operation
    • Provides for single unit stand-alone operation,island mode paralleling and load sharing withother power modules, and single unit-to-utilitymode paralleling for base load control
  • General
    • Fire detection system
  • Lube Oil Make-Up System
    • Integrated enclousre holding tanks: Oil makeup tank (50 gallon), Waste oil tank (300 gal / 2 oil changes), Fresh oil tank (500 gal / 2 oil changes + makeup) and oil level regulator. Low level annunciation
  • Circuit Breaker
    • 5000A 3-Pole IEC Rated Circuit Breakers
    • LSI Long-Time, Short-Time, Instantaneous Annunciator
    • Rear-mounted
  • Exhaust
    • Externally mounted exhaust system (muffler and heat exchanger)
    • Dry exhaust manifolds, insulated and shielded
    • Center section cooled turbocharger with Cat flanged outlet
    • Individual exhaust port and turbocharger outlet wired to Integrated Tmeperature Sensing Module (ITSM) with GECM providing alarms and shutdowns
  • Fuel System
    • Electronic fuel metering valve
    • Throttle plate, 24V DC actuator, controlled by GECM
  • Fuel system
    • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • Ignition System
    • Individual Cylinder Detonation Sensitive Timing (DST)
    • Electronic Ignition System (controlled by ADEM A4)
  • Generator
    • Double bearing SR5 1866 frame, brushless, form wound, 12-lead design, permanent magnet excited, three-phase, with Cat IVR, Class H insulation operating at Class F temperature. Stator and Bearing temperature monitoring and anti-condensation space heaters.
    • SR4B
    • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
    • Busbar connections
    • Paint- Caterpillar Yellow except rails gloss black
    • Winding temperature detectors
    • Parts book
    • RH Service
    • Anti-condensation space heater
    • SR5
    • Operation and maintenance manuals
    • Crankshaft Vibration Damper and Guard
    • Reactive droop
  • Govrerning System
    • ADEM A4 4-20mA (0-5VV) Speed Input

Optional Equipment

  • Air Inlet
    • Mounting Brackets and Piping
    • Air cleaner with precleaner
  • Circuit Breaker
    • MP- Frame 6 Pole Bottom Cable Entry
    • Frame Mounting
    • 4000/5000A Neutral Current Transformer Automatic Selection
    • No UV trip or package mounted CB Wiring
  • Control Panel
    • Discrete I/O Module, 12 Digital Inputs, 8 'Form C' Relay
    • Local PC Monitorring
    • 16 Point/32 Light Annunciator, Shipped Loose
    • Remote PC Monitorring
    • Synchronizing module
    • Remote annuciator
    • Local alarm module
    • Engine failure relay
    • Cat Connect: Ehternet, Satellite, Cell Telematics
    • Remote Communications Module (PL1000T, PL1000E)
  • Cooling
    • Inlet/Outlet connections
    • Coolant level drain line with valves, fan with guard
  • Exhaust
    • Muffler and spark-arresting muffler with companion flanges
    • Elbow
    • Flange
    • Flexible Fitting
    • Exhaust Expander
    • Oxidation catalyst
  • Fuel System
    • Gas pressure regulator
    • Gas Knockdown Regulator
    • Fuel filter
    • Gas shutoff valve 24V, ETR (Energized-To-Run)
  • Generator
    • European bus bar
    • Cable access box
    • Manual voltage control
    • Medium and high voltage generators and attachment
    • Low voltage extension box
    • Bearing temperature detectors
    • Generator air filter
  • General
    • Special paint order
    • Tool set
    • Digital diagnostic tool
    • US AID Emblem
    • Cold-weather bundle including enclosure heaters and ventilation recirculation
    • Fire suppression system
    • Interior DC lighting system with automatic shutoff timer
  • Starting/Charging
    • 24V starting motors
    • Jacket water heater
    • Battery with cables and rack (shipped loose)
    • 60A, 24V charging alternator (requires engine driven pumps)