Technicial Specifications
Emissions/Fuel Strategy | U.S. EPA Tier 2 S.I. Non Road Mobile U.S. EPA Tier 2 S.I. Non Road Mobile |
Aspiration | Turbocharged-2 stage after cooled Turbocharged-2 stage after cooled |
Bore | 6.7 in 170 mm |
Stroke | 7.5 in 190 mm |
Displacement | 3173 in³ 52 l |
Engine Control and Protection | Electronic (ADEM 4) Electronic (ADEM 4) |
Generator Set Control | EMCP 4.4 Control Panels EMCP 4.4 Control Panels |
Frequency - Speed | 60 Hz 60 Hz |
Fuel System | Electronic Fuel Control Valve Electronic Fuel Control Valve |
Length | 196 in 4979.3 mm |
Width | 84.8 in 2154.4 mm |
Height | 89.6 in 2277.1 mm |
Advantages and Features
Genset Design
- Meets U.S. EPA Large SI Tier 2.*
- Genset designed to be paired with the Cat® energy storage system for a complete drilling factory solution
- Engine design built on the G3500 platform with proven reliability and durability
- EMCP 4.4 shipped standard • Jacket water and lube oil heaters shipped standard
- Rugged package base designed for oil fields
Emissions
Lean air/fuel mixture provides best available emissions and fuel efficiency for engines of this bore sizeAdvanced Digital Engine Management
ADEM™4 (A4) engine management system integrates speed control, air/fuel ratio control, and ignition/detonation controls into a complete engine management system. The ADEM™4 (A4) has an improved: user interface, display system, shutdown controls, and system diagnostics.Full Range of Attachments
Large variety of factory-installed package attachments reduces packaging timeTesting
Every genset is full-load tested to ensure proper package performance.Standard Equipment
-
Air Inlet System
- Air cleaner, intermediate duty, with service indicator and air filter differential pressure sensors
-
Cooling System
- Jacket water outlet- right hand flange connection
- Jacket water pump, gear driven, centrifugal, non - priming
-
Exhaust System
- Dry exhaust manifold
-
Fuel System
- 10-35 kPag gas supply
-
Instrumentation
- EMCP 4.4
- ADEM™4
-
Lubrication System
- Crankcase breather - top mounted
- Prelube pump
- Simplex oil filter
- Standard Oil Pan
Optional Equipment
-
Air Inlet System
- Pre-cleaners
-
Charging Alternator
- Charging alternator 24V, 35A
-
Connections
- Left hand flanged jacket water connection
-
Exhaust System
- Exhaust weld flange
-
Fuel System
- Gas train
-
Lubrication System
- Electric prelube
- Air prelube
- Oil level regulator
- Oil drain
-
Starting System
- Barring group
- Right hand air starter